APPLICATION
QALCOSONIC W2 accurately measures water consumption and enables remote water supply management through its integrated valve. It helps utilities secure timely payments and manage water infrastructure more efficiently, while giving users greater visibility into their water use.
- Static method of water flow measurement, no moving parts
- High accuracy of water consumption measurement
- Eliminates measuring deviations caused by sand, suspended particles or air pockets
- Long-term measurement stability and reliability
- 10-digit, multi-line LCD. Total volume and instantaneous flow rate indication
- Sensitive and accurate at low flows, down to 1 l/h
- Failsafe mechanisms in place for every real-life scenario
- Configurable physical button on the housing
- Daily consumption mode enables setting a daily usage limit in litres
- Valve health monitoring
- Configurable partial valve position
- Equipped with NFC, wM-Bus, LoRa and NB-IoT technologies
AMR READY
- wM-Bus 433 or 868 MHz OMS T1
- LoRaWAN (EU863-870, AS923, AU915-928, US902-928, IN865-867 channel plans)
- NB-IoT (CoAP, DLMS)
- NFC
PARAMETERISATION
- NFC and optical interfaces on the top panel enable meter data reading and parameterisation
- Valve and meter parameterisation is available over the air (COTA)
- Meter firmware update is available over the air (FOTA)
- Meter parameterisation and archive reading via NFC, optical interface or remotely
TECHNICAL FEATURES
- Temperature class T30, T50, T30/90, T90
- Nominal flow 1.6 / 2.5 / 4.0 m³/h
- Wide measurement range Q3/Q1 = 80 / 160 / 250 / 315 / 400 / 500 / 800
- No straight pipe sections required before or after the meter
- Installation in any position
- No measurement of air
- Electromagnetic environment class E2
- Mechanical environment class M1
- Protection class IP68
- Nominal pressure PN16
- Internal datalogger
- Maintenance-free device, battery lifetime up to 16 years*
- Bi-directional flow measurements
- Flow direction indication
- Meter parameterisation and archive reading via NFC, optical interface or remotely
- Brass and composite body options
- Tamper detection mechanism
- Self-cleaning valve mechanism
Depending on communication and valve settings.
DATA LOGGER & ALARMS
- Hourly, daily and monthly values of measured parameters are stored in internal memory
- Integrated radio communication allows data reading via wM-Bus telegram: 433 MHz or 868 MHz OMS T1 mode, LoRaWAN or NB-IoT
- Multiple alarms and events, including:
- Flow direction indication
- Battery level indication
- Leakage
- Burst
- Backflow
- Empty pipe
- Signal strength
- Warning indication
- Low-temperature warning
TECHNICAL DATA
- Flow sensor Q3: 1.6 / 2.5 / 4.0 m³/h
- R Q3/Q1: 80 / 160 / 250 / 315 / 400 / 500 / 800
- Water temperature: 0.1–90°C
- LCD display: 10 digits
- Protection class: IP68
- Environmental class: B (Indoors) / O (Outdoors) / ISO 4064
- Ambient temperature: -15°C to +70°C
- Installation position: All installation positions – vertically, horizontally or diagonally
- Nominal pressure: PN16 bar
- Pressure loss: 0.16 / 0.25 / 0.40
- Battery lifetime: Up to 16 years, depending on communication and valve settings
- Units: m³ / m³/h
SIZE & DIMENSIONS
- DN15: L 110 mm, 165 mm
- DN20: L 130 mm, 165 mm, 190 mm
- DN15 connection: G ¾"
- DN20 connection: G 1"
* Composite only
** Brass only
APPLICATION
QALCOSONIC W2 accurately measures water consumption and enables remote water supply management through its integrated valve. It helps utilities secure timely payments and manage water infrastructure more efficiently, while giving users greater visibility into their water use.
- Static method of water flow measurement, no moving parts
- High accuracy of water consumption measurement
- Eliminates measuring deviations caused by sand, suspended particles or air pockets
- Long-term measurement stability and reliability
- 10-digit, multi-line LCD. Total volume and instantaneous flow rate indication
- Sensitive and accurate at low flows, down to 1 l/h
- Failsafe mechanisms in place for every real-life scenario
- Configurable physical button on the housing
- Daily consumption mode enables setting a daily usage limit in litres
- Valve health monitoring
- Configurable partial valve position
- Equipped with NFC, wM-Bus, LoRa and NB-IoT technologies
AMR READY
- wM-Bus 433 or 868 MHz OMS T1
- LoRaWAN (EU863-870, AS923, AU915-928, US902-928, IN865-867 channel plans)
- NB-IoT (CoAP, DLMS)
- NFC
PARAMETERISATION
- NFC and optical interfaces on the top panel enable meter data reading and parameterisation
- Valve and meter parameterisation is available over the air (COTA)
- Meter firmware update is available over the air (FOTA)
- Meter parameterisation and archive reading via NFC, optical interface or remotely
TECHNICAL FEATURES
- Temperature class T30, T50, T30/90, T90
- Nominal flow 1.6 / 2.5 / 4.0 m³/h
- Wide measurement range Q3/Q1 = 80 / 160 / 250 / 315 / 400 / 500 / 800
- No straight pipe sections required before or after the meter
- Installation in any position
- No measurement of air
- Electromagnetic environment class E2
- Mechanical environment class M1
- Protection class IP68
- Nominal pressure PN16
- Internal datalogger
- Maintenance-free device, battery lifetime up to 16 years*
- Bi-directional flow measurements
- Flow direction indication
- Meter parameterisation and archive reading via NFC, optical interface or remotely
- Brass and composite body options
- Tamper detection mechanism
- Self-cleaning valve mechanism
Depending on communication and valve settings.
DATA LOGGER & ALARMS
- Hourly, daily and monthly values of measured parameters are stored in internal memory
- Integrated radio communication allows data reading via wM-Bus telegram: 433 MHz or 868 MHz OMS T1 mode, LoRaWAN or NB-IoT
- Multiple alarms and events, including:
- Flow direction indication
- Battery level indication
- Leakage
- Burst
- Backflow
- Empty pipe
- Signal strength
- Warning indication
- Low-temperature warning
TECHNICAL DATA
- Flow sensor Q3: 1.6 / 2.5 / 4.0 m³/h
- R Q3/Q1: 80 / 160 / 250 / 315 / 400 / 500 / 800
- Water temperature: 0.1–90°C
- LCD display: 10 digits
- Protection class: IP68
- Environmental class: B (Indoors) / O (Outdoors) / ISO 4064
- Ambient temperature: -15°C to +70°C
- Installation position: All installation positions – vertically, horizontally or diagonally
- Nominal pressure: PN16 bar
- Pressure loss: 0.16 / 0.25 / 0.40
- Battery lifetime: Up to 16 years, depending on communication and valve settings
- Units: m³ / m³/h
SIZE & DIMENSIONS
- DN15: L 110 mm, 165 mm
- DN20: L 130 mm, 165 mm, 190 mm
- DN15 connection: G ¾"
- DN20 connection: G 1"
* Composite only